Rbw¶
SCPI Commands
CONFigure:EVDO:MEASurement<Instance>:MEValuation:ACP:EXTended:RBW:LOWer
CONFigure:EVDO:MEASurement<Instance>:MEValuation:ACP:EXTended:RBW:UPPer
- class Rbw[source]
Rbw commands group definition. 2 total commands, 0 Sub-groups, 2 group commands
- get_lower() → List[RsCmwEvdoMeas.enums.Rbw][source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:RBW:LOWer value: List[enums.Rbw] = driver.configure.multiEval.acp.extended.rbw.get_lower()
Defines the resolution bandwidth to be used for lower frequency offset 19 to 0 of the selected carrier for extended ACP measurements (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) .
- return
rbw: F1K0 | F6K25 | F10K | F12K5 | F25K | F30K | F50K | F100k | F1M0 | F1M23 F1K0: 1 kHz F6K25: 6.25 kHz F10K: 10 kHz F12K5: 12.5 kHz F25K: 25 kHz F30K: 30 kHz F50K: 50 kHz F100k: 100 kHz F1M0: 1 MHz F1M23: 1.23 MHz Unit: Hz
- get_upper() → List[RsCmwEvdoMeas.enums.Rbw][source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:RBW:UPPer value: List[enums.Rbw] = driver.configure.multiEval.acp.extended.rbw.get_upper()
Defines the resolution bandwidth to be used for upper frequency offset 0 to 9 of the selected carrier for extended ACP measurements (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) .
- return
rbw: F1K0 | F6K25 | F10K | F12K5 | F25K | F30K | F50K | F100k | F1M0 | F1M23 F1K0: 1 kHz F6K25: 6.25 kHz F10K: 10 kHz F12K5: 12.5 kHz F25K: 25 kHz F30K: 30 kHz F50K: 50 kHz F100k: 100 kHz F1M0: 1 MHz F1M23: 1.23 MHz Unit: Hz
- set_lower(rbw: List[RsCmwEvdoMeas.enums.Rbw]) → None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:RBW:LOWer driver.configure.multiEval.acp.extended.rbw.set_lower(rbw = [Rbw.F100k, Rbw.F6K25])
Defines the resolution bandwidth to be used for lower frequency offset 19 to 0 of the selected carrier for extended ACP measurements (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) .
- param rbw
F1K0 | F6K25 | F10K | F12K5 | F25K | F30K | F50K | F100k | F1M0 | F1M23 F1K0: 1 kHz F6K25: 6.25 kHz F10K: 10 kHz F12K5: 12.5 kHz F25K: 25 kHz F30K: 30 kHz F50K: 50 kHz F100k: 100 kHz F1M0: 1 MHz F1M23: 1.23 MHz Unit: Hz
- set_upper(rbw: List[RsCmwEvdoMeas.enums.Rbw]) → None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:RBW:UPPer driver.configure.multiEval.acp.extended.rbw.set_upper(rbw = [Rbw.F100k, Rbw.F6K25])
Defines the resolution bandwidth to be used for upper frequency offset 0 to 9 of the selected carrier for extended ACP measurements (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) .
- param rbw
F1K0 | F6K25 | F10K | F12K5 | F25K | F30K | F50K | F100k | F1M0 | F1M23 F1K0: 1 kHz F6K25: 6.25 kHz F10K: 10 kHz F12K5: 12.5 kHz F25K: 25 kHz F30K: 30 kHz F50K: 50 kHz F100k: 100 kHz F1M0: 1 MHz F1M23: 1.23 MHz Unit: Hz