Foffsets¶
SCPI Commands
CONFigure:EVDO:MEASurement<Instance>:MEValuation:ACP:EXTended:FOFFsets:LOWer
CONFigure:EVDO:MEASurement<Instance>:MEValuation:ACP:EXTended:FOFFsets:UPPer
- class Foffsets[source]
Foffsets commands group definition. 2 total commands, 0 Sub-groups, 2 group commands
- get_lower() → List[float][source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:FOFFsets:LOWer value: List[float or bool] = driver.configure.multiEval.acp.extended.foffsets.get_lower()
Defines the negative (lower) frequency offsets 19 to 0, to be used for extended ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 20 offsets can be defined and enabled. The offset index 19 to 0 corresponds to the index used in manual control.
- return
frequency_offset: Range: -4 MHz to 0 MHz Additional parameters: OFF | ON (disables | enables the offset)
- get_upper() → List[float][source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:FOFFsets:UPPer value: List[float or bool] = driver.configure.multiEval.acp.extended.foffsets.get_upper()
Defines the positive (upper) frequency offsets 0 to 19, to be used for extended ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 20 offsets can be defined and enabled. The offset index 0 to 19 corresponds to the index used in manual control.
- return
frequency_offset: Range: 0 MHz to 4 MHz , Unit: Hz Additional parameters: OFF | ON (disables | enables the offset)
- set_lower(frequency_offset: List[float]) → None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:FOFFsets:LOWer driver.configure.multiEval.acp.extended.foffsets.set_lower(frequency_offset = [1.1, True, 2.2, False, 3.3])
Defines the negative (lower) frequency offsets 19 to 0, to be used for extended ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 20 offsets can be defined and enabled. The offset index 19 to 0 corresponds to the index used in manual control.
- param frequency_offset
Range: -4 MHz to 0 MHz Additional parameters: OFF | ON (disables | enables the offset)
- set_upper(frequency_offset: List[float]) → None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:EXTended:FOFFsets:UPPer driver.configure.multiEval.acp.extended.foffsets.set_upper(frequency_offset = [1.1, True, 2.2, False, 3.3])
Defines the positive (upper) frequency offsets 0 to 19, to be used for extended ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 20 offsets can be defined and enabled. The offset index 0 to 19 corresponds to the index used in manual control.
- param frequency_offset
Range: 0 MHz to 4 MHz , Unit: Hz Additional parameters: OFF | ON (disables | enables the offset)