Scount¶
SCPI Commands
CONFigure:EVDO:MEASurement<Instance>:MEValuation:SCOunt:MODulation
CONFigure:EVDO:MEASurement<Instance>:MEValuation:SCOunt:SPECtrum
- class Scount[source]
Scount commands group definition. 2 total commands, 0 Sub-groups, 2 group commands
- get_modulation() → int[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:SCOunt:MODulation value: int = driver.configure.multiEval.scount.get_modulation()
Specifies the statistic count of the measurement. The statistic count is equal to the number of measurement intervals per single shot.
- return
scount_mod: numeric Number of measurement intervals. Range: 1 to 1000
- get_spectrum() → int[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:SCOunt:SPECtrum value: int = driver.configure.multiEval.scount.get_spectrum()
Specifies the statistic count of the measurement. The statistic count is equal to the number of measurement intervals per single shot.
- return
scount_spectrum: numeric Number of measurement intervals. Range: 1 to 1000
- set_modulation(scount_mod: int) → None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:SCOunt:MODulation driver.configure.multiEval.scount.set_modulation(scount_mod = 1)
Specifies the statistic count of the measurement. The statistic count is equal to the number of measurement intervals per single shot.
- param scount_mod
numeric Number of measurement intervals. Range: 1 to 1000
- set_spectrum(scount_spectrum: int) → None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:SCOunt:SPECtrum driver.configure.multiEval.scount.set_spectrum(scount_spectrum = 1)
Specifies the statistic count of the measurement. The statistic count is equal to the number of measurement intervals per single shot.
- param scount_spectrum
numeric Number of measurement intervals. Range: 1 to 1000