Modulation¶
SCPI Commands
CONFigure:EVDO:MEASurement<Instance>:MEValuation:LIST:SEGMent<Segment>:MODulation
- class Modulation[source]
Modulation commands group definition. 1 total commands, 0 Sub-groups, 1 group commands
- class ModulationStruct[source]
Structure for setting input parameters. Contains optional setting parameters. Fields:
Statistic_Length: int: integer The statistical length is limited by the number of steps in the segment which is defined by [CMDLINK: CONFigure:EVDO:MEASi:MEValuation:LIST:SEGMentno:SETup CMDLINK].
Enable_Evm: bool: OFF | ON OFF: Disable measurement. ON: Enable measurement of EVM.
Enable_Mag_Error: bool: OFF | ON Disable or enable measurement of magnitude error.
Enable_Phase_Err: bool: OFF | ON Disable or enable measurement of phase error.
Enable_Wave_Qual: bool: OFF | ON Disable or enable measurement of waveform quality.
Enable_Iq_Error: bool: OFF | ON Disable or enable measurement of I/Q origin offset and imbalance.
Enable_Ch_Pow: bool: OFF | ON Disable or enable measurement of channel power.
Enable_Dwcp: bool: OFF | ON Disable or enable measurement of data Walsh code channel power.
Enable_Wbnb_Pow: bool: OFF | ON Disable or enable measurement of wideband and narrowband power.
Enable_Freq_Err: bool: OFF | ON Disable or enable measurement of carrier frequency error.
Enable_Melm_Tte: bool: Optional setting parameter. OFF | ON Disable or enable measurement of transmit time error.
- get(segment=<Segment.Default: -1>) → ModulationStruct[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:LIST:SEGMent<nr>:MODulation value: ModulationStruct = driver.configure.multiEval.listPy.segment.modulation.get(segment = repcap.Segment.Default)
Defines the statistical length for AVERage, MAXimum, MINimum and SDEViation calculation and enables the calculation of the different modulation results in segment <no>; see ‘Multi-Evaluation List Mode’.
- param segment
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)
- return
structure: for return value, see the help for ModulationStruct structure arguments.
- set(structure: RsCmwEvdoMeas.Implementations.Configure_.MultiEval_.ListPy_.Segment_.Modulation.Modulation.ModulationStruct, segment=<Segment.Default: -1>) → None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:LIST:SEGMent<nr>:MODulation driver.configure.multiEval.listPy.segment.modulation.set(value = [PROPERTY_STRUCT_NAME](), segment = repcap.Segment.Default)
Defines the statistical length for AVERage, MAXimum, MINimum and SDEViation calculation and enables the calculation of the different modulation results in segment <no>; see ‘Multi-Evaluation List Mode’.
- param structure
for set value, see the help for ModulationStruct structure arguments.
- param segment