Foffsets

SCPI Commands

CONFigure:EVDO:MEASurement<Instance>:MEValuation:ACP:FOFFsets:LOWer
CONFigure:EVDO:MEASurement<Instance>:MEValuation:ACP:FOFFsets:UPPer
class Foffsets[source]

Foffsets commands group definition. 2 total commands, 0 Sub-groups, 2 group commands

get_lower()List[float][source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:FOFFsets:LOWer
value: List[float or bool] = driver.configure.multiEval.acp.foffsets.get_lower()

Defines the negative (lower) frequency offsets to be used for ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 10 offsets can be defined and enabled. The offset index 0 to 9 corresponds to the index used in manual control.

return

frequency_offset: No help available

get_upper()List[float][source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:FOFFsets:UPPer
value: List[float or bool] = driver.configure.multiEval.acp.foffsets.get_upper()

Defines the positive (upper) frequency offsets to be used for ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 10 offsets can be defined and enabled. The offset index 0 to 9 corresponds to the index used in manual control.

return

frequency_offset: No help available

set_lower(frequency_offset: List[float])None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:FOFFsets:LOWer
driver.configure.multiEval.acp.foffsets.set_lower(frequency_offset = [1.1, True, 2.2, False, 3.3])

Defines the negative (lower) frequency offsets to be used for ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 10 offsets can be defined and enabled. The offset index 0 to 9 corresponds to the index used in manual control.

param frequency_offset

numeric | ON | OFF Range: -4 MHz to 0 MHz, Unit: MHz Additional parameters: OFF | ON (disables | enables the offset)

set_upper(frequency_offset: List[float])None[source]
# SCPI: CONFigure:EVDO:MEASurement<instance>:MEValuation:ACP:FOFFsets:UPPer
driver.configure.multiEval.acp.foffsets.set_upper(frequency_offset = [1.1, True, 2.2, False, 3.3])

Defines the positive (upper) frequency offsets to be used for ACP measurements of the selected carrier (see method RsCmwEvdoMeas.Configure.MultiEval.Carrier.select) . The offsets are defined relative to the analyzer frequency. Up to 10 offsets can be defined and enabled. The offset index 0 to 9 corresponds to the index used in manual control.

param frequency_offset

numeric | ON | OFF Range: 0 MHz to 4 MHz, Unit: MHz Additional parameters: OFF | ON (disables | enables the offset)