State¶
SCPI Commands
READ:EVDO:MEASurement<Instance>:OLTR:SEQuence<Sequence>:TRACe:UP:STATe
FETCh:EVDO:MEASurement<Instance>:OLTR:SEQuence<Sequence>:TRACe:UP:STATe
CALCulate:EVDO:MEASurement<Instance>:OLTR:SEQuence<Sequence>:TRACe:UP:STATe
- class State[source]
State commands group definition. 3 total commands, 0 Sub-groups, 3 group commands
- calculate(sequence=<Sequence.Default: -1>) → List[RsCmwEvdoMeas.enums.ResultStatus2][source]
# SCPI: CALCulate:EVDO:MEASurement<instance>:OLTR:SEQuence<Sequence>:TRACe:UP:STATe value: List[enums.ResultStatus2] = driver.oltr.sequence.trace.up.state.calculate(sequence = repcap.Sequence.Default)
For each sequence, state commands return limit violation results ‘State Down/Up Power’ in 20 equidistant parts of the 100 ms interval following the power down/up step. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Use RsCmwEvdoMeas.reliability.last_value to read the updated reliability indicator.
- param sequence
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Sequence’)
- return
state_up_power: No help available
- fetch(sequence=<Sequence.Default: -1>) → List[RsCmwEvdoMeas.enums.StatePower][source]
# SCPI: FETCh:EVDO:MEASurement<instance>:OLTR:SEQuence<Sequence>:TRACe:UP:STATe value: List[enums.StatePower] = driver.oltr.sequence.trace.up.state.fetch(sequence = repcap.Sequence.Default)
For each sequence, state commands return limit violation results ‘State Down/Up Power’ in 20 equidistant parts of the 100 ms interval following the power down/up step. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Use RsCmwEvdoMeas.reliability.last_value to read the updated reliability indicator.
- param sequence
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Sequence’)
- return
state_up_power: No help available
- read(sequence=<Sequence.Default: -1>) → List[RsCmwEvdoMeas.enums.StatePower][source]
# SCPI: READ:EVDO:MEASurement<instance>:OLTR:SEQuence<Sequence>:TRACe:UP:STATe value: List[enums.StatePower] = driver.oltr.sequence.trace.up.state.read(sequence = repcap.Sequence.Default)
For each sequence, state commands return limit violation results ‘State Down/Up Power’ in 20 equidistant parts of the 100 ms interval following the power down/up step. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Use RsCmwEvdoMeas.reliability.last_value to read the updated reliability indicator.
- param sequence
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Sequence’)
- return
state_up_power: No help available