Current¶
SCPI Commands
FETCh:EVDO:MEASurement<Instance>:MEValuation:LIST:SEGMent<Segment>:CP:CURRent
CALCulate:EVDO:MEASurement<Instance>:MEValuation:LIST:SEGMent<Segment>:CP:CURRent
- class Current[source]
Current commands group definition. 2 total commands, 0 Sub-groups, 2 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliabiltiy: int: decimal ‘Conventions and General Information’. In list mode, a zero reliability indicator indicates that the results in all measured segments are valid. A non-zero value indicates that an error occurred in at least one of the measured segments.
Seg_Reliability: int: 0 | 3 | 4 | 8 The segment reliability indicates whether one of the following exceptions occurred in this segment: 0: No error 3: Signal overflow 4: Signal low 8: Synchronization error If a combination of exceptions occurs, the most severe error is indicated.
Rri: enums.ResultStatus2: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Pilot: enums.ResultStatus2: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Ack_Dsc: enums.ResultStatus2: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Aux_Pilot: enums.ResultStatus2: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Drc: enums.ResultStatus2: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Data: enums.ResultStatus2: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
- class FetchStruct[source]
Response structure. Fields:
Reliabiltiy: int: decimal ‘Conventions and General Information’. In list mode, a zero reliability indicator indicates that the results in all measured segments are valid. A non-zero value indicates that an error occurred in at least one of the measured segments.
Seg_Reliability: int: 0 | 3 | 4 | 8 The segment reliability indicates whether one of the following exceptions occurred in this segment: 0: No error 3: Signal overflow 4: Signal low 8: Synchronization error If a combination of exceptions occurs, the most severe error is indicated.
Rri: float: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Pilot: float: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Ack_Dsc: float: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Aux_Pilot: float: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Drc: float: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
Data: float: float RMS channel power values for the physical channels. Depending on the subtype 0/1 or 2, some channels exist or not. If not available, no power measurement is possible therefore NAV is returned. Range: -60 dB to +10 dB , Unit: dB
- calculate(segment=<Segment.Default: -1>) → CalculateStruct[source]
# SCPI: CALCulate:EVDO:MEASurement<instance>:MEValuation:LIST:SEGMent<nr>:CP:CURRent value: CalculateStruct = driver.multiEval.listPy.segment.cp.current.calculate(segment = repcap.Segment.Default)
Returns channel power (CP) results for the segment <no> in list mode. To define the statistical length for AVERage, MAXimum, MINimum calculation and enable the calculation of the results use the command method RsCmwEvdoMeas.Configure. MultiEval.ListPy.Segment.Modulation.set. The values described below are returned by FETCh commands. CALCulate commands return limit check results instead, one value for each result listed below.
- param segment
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)
- return
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch(segment=<Segment.Default: -1>) → FetchStruct[source]
# SCPI: FETCh:EVDO:MEASurement<instance>:MEValuation:LIST:SEGMent<nr>:CP:CURRent value: FetchStruct = driver.multiEval.listPy.segment.cp.current.fetch(segment = repcap.Segment.Default)
Returns channel power (CP) results for the segment <no> in list mode. To define the statistical length for AVERage, MAXimum, MINimum calculation and enable the calculation of the results use the command method RsCmwEvdoMeas.Configure. MultiEval.ListPy.Segment.Modulation.set. The values described below are returned by FETCh commands. CALCulate commands return limit check results instead, one value for each result listed below.
- param segment
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)
- return
structure: for return value, see the help for FetchStruct structure arguments.